SBS sets

SBS sets: two SA contactors with mechanical interlocking

Construction
SBS set consist of two SA contactors located on the same board and coupled through the mechanical interlocking. In this system it is possible to switch on in the given moment only one of these contactors. After switching on one of the contactors, the second one is mechanically blocked.

Application
The SBS set is intended only for swit-ching AC circuits. It can be used in the systems for automatic switching to reserve supply, in reversible systems and in all situations, where mistakenly executed switching on of two contactors in the same time leads to short circuit and possible damage of the equipment. These systems shall also have additional electrical interlocking. For this one shall connect in series the coils of each of the contactors included in this interlocking with the NC contact of the auxiliary switch belonging to the other contactor. Each contactor has got on one side auxiliary switches 1NO + 2NC or 3NO+3NC. When using automatic control it is necessary to set delay between the subsequent operations of the contactors, which is notshorter then 1 s, due to inertia of the mechanical interlocking system. The other technical parameters of contractors can be found in the relevant catalogue at pages 5 ÷ 9.


Product range

Set type

Identification No
Item No.
-
A
-
C
SB55M
K115 025
T
603-T08...
SB75M
K115 026
T
603-T07...
SB90M
K115 027
T
603-T06...
SB110M
K115 028
T
603-T05...
SB132
K115 029
T
603-T04...
SB160
K115 030
T
603-T03...
SB200
K115 032
T
603-T02...
SB250
K115 034
T
603-T01...


A – Coil voltage (50Hz)
| 4 | 110 V
| 3 | 230 V
| 5 | 400 V
| 8 | 500 V


B - Auxiliary contacts number
| 1 | 1 |
2z+4r
| 1 | 2 |
6z+6r


Technical data

Set type
SBS55M
SBS75M
SBS90M
SBS110M
SBS132
SBS160
SBS200
SBS250
Class CC CC CC PC PC PC PC PC
Rated continous current Iu
[A]
150
180
200
220
250
300
400
550
Contactor type
-
SA55M
SA75M
SA90M
SA110M
SA132
SA160
SA200
SA250
Weight
[kg]
8,8
9
9,4
10
21,2
21,4
21,8
22,6


Ordering example

Set including two contactors with mechanical interlocking SBS for continuos current (Iu) 250 A, with control voltage 400 V and with auxiliary switches 6NC+6NO SBS 132 6NC+6NO 400V 50Hz K125 0295 T12


Dimensions


Type
A
B
C
G
L
2z+2r
6z+6r
SBS 55M/75M/90M
42
50
20
M8
266
285
SBS 110M
48
28
25
M10



Type
A
B
C
G
L
2z+2r
6z+6r
SBS 132/160/200
48
84
25
M10
360
380
SBS 250
53
73
30
M12