Brass gland MWD and
MWD...M types
for protective conduits IP66
Used as
a termination of spiral protective
conduits where conductors are inserted into the inside of electrical
devices. Recommended for WO, WOT conduits.
The tube is screwed into the gland. Consequently,
with WO or WOT conduit the
IP66 class can be provided.
Material:
nickel-plated brass+polyethylene.
Working
temperature: -5÷+80
°C ( without moving
-20°C).

|
Type
|
Thread
PG
|
Min. internal diameter C [mm]
|
Height
L [mm]
|
Thread
length E [mm]
|
SpannerNo.
[mm]
|
Pack [pcs.]
|
Art. No.
|
|
A
|
B
|
|
MWD 7
|
P 7
|
7,5
|
10,0
|
6
|
19
|
17
|
50
|
E03DK-08010100101
|
|
MWD 9
|
P 9
|
9,2
|
12,5
|
6
|
22
|
20
|
50
|
E03DK-08010100201
|
|
MWD 11
|
P 11
|
11,9
|
13,0
|
7
|
26
|
24
|
50
|
E03DK-08010100301
|
|
MWD 13
|
P 13,5
|
13,6
|
13,0
|
7
|
28
|
26
|
50
|
E03DK-08010100401
|
|
MWD 16
|
P 16
|
15,3
|
14,0
|
8
|
30
|
28
|
50
|
E03DK-08010100501
|
|
MWD 21
|
P 21
|
20,2
|
16,5
|
8
|
36
|
34
|
25
|
E03DK-08010100601
|
|
MWD 29
|
P 29
|
26,7
|
13,5
|
10
|
47
|
45
|
25
|
E03DK-08010100701
|
|
MWD 36
|
P 36
|
34,6
|
26,5
|
11
|
60
|
56
|
10
|
E03DK-08010100801
|
|
MWD 48
|
P 48
|
45,3
|
33,0
|
15
|
74
|
70
|
10
|
E03DK-08010100901
|
|
Type
|
Thread / Conduits
M (ISO) / WO (WOT)
|
Min. internal diameter
C
[mm]
|
Height
L
[mm]
|
Thread
length
E
[mm]
|
Spanner
No.
[mm]
|
Pack [pcs.]
|
Art. No.
|
|
A
|
B
|
|
MWD 12M/7
|
M 12x1,5 / 7
|
7,5
|
10,2
|
6
|
19
|
17
|
50
|
E03DK-08010200101
|
|
MWD 16M/9
|
M 16x1,5 / 9
|
9,2
|
12,5
|
6
|
22
|
20
|
50
|
E03DK-08010200201
|
|
MWD 20M/11
|
M 20x1,5 / 11
|
11,9
|
13
|
7
|
26
|
24
|
50
|
E03DK-08010200301
|
|
MWD 20M/13
|
M 20x1,5 / 13
|
13,6
|
13,2
|
7
|
28
|
26
|
50
|
E03DK-08010200401
|
|
MWD 25M/16
|
M 25x1,5 / 16
|
15,3
|
14
|
8
|
30
|
28
|
25
|
E03DK-08010200501
|
|
MWD 25M/21
|
M 25x1,5 / 21
|
20,2
|
16,5
|
6,5
|
36
|
36
|
25
|
E03DK-08010200601
|
|
MWD 32M/21
|
M 32x1,5 / 21
|
20,2
|
16,5
|
8
|
36
|
36
|
25
|
E03DK-08010200701
|
|
MWD 32M/29
|
M 32x1,5 / 29
|
26,7
|
19,5
|
6,5
|
47
|
45
|
25
|
E03DK-08010200801
|
|
MWD 40M/29
|
M 40x1,5 / 29
|
26,7
|
19,5
|
10
|
47
|
45
|
10
|
E03DK-08010200901
|
|
MWD 40M/36
|
M 40x1,5 / 36
|
34,6
|
26
|
8,5
|
60
|
56
|
10
|
E03DK-08010201001
|
|
MWD 50M/36
|
M 50x1,5 / 36
|
34,6
|
26
|
11
|
60
|
58
|
10
|
E03DK-08010201101
|
|
MWD 63M/48
|
M 63x1,5 / 48
|
45,3
|
32,5
|
15
|
74
|
70
|
10
|
E03DK-08010201201
|
Note!
Nuts
MDN and gland seals have to be ordered separately.Upon
request metric threaded glands MWT type are available.We
also offer nickel – plated
brass glands, operating at temperatures up to 800 °C (for WO
and WO...S condnits) with PG thread, IP40.
Glands MWE with metal insert for WO and WOTconduits, size 63; 75 and 100
| Material: |
body: zink alloy |
|
|
insert: galvanized steel + rubber |
|
lock nut: galvanized steel (ST) or zink alloy (ZN) |
|
sealings washer: rubber |
| Working temperature: |
-20÷+80 °C |
MWE G G type thread
| Type |
Thread / conduit
G / WOT |
Inner dia. min. |
Height |
Thread length |
Spanner No. (octagon) |
Lock nut |
Pack.
pcs. |
Art. No. |
| C |
L |
E |
A |
B |
D1 |
D2 |
S |
| [mm] |
[mm] |
|
MWE G2 1/2"/63
|
G2 1/2" / 63
|
60
|
40
|
22
|
88
|
86
|
94
|
88
|
4,5 (ST)
|
1
|
E03DK-08010300101
|
|
MWE G3"/75
|
G3" / 75
|
74
|
44
|
23
|
106
|
102
|
106
|
101
|
4,5 (ST)
|
1
|
E03DK-08010300201
|
|
MWE G4"/100
|
G4" / 100
|
96
|
50
|
28
|
134
|
130
|
134
|
128
|
10 (ZN)
|
1
|
E03DK-08010300301
|
Note!
Set with lock nut and sealing washer.
MWE ..M metric thread
| Type |
Thread / conduit
M / WOT |
Inner dia. min. |
Height |
Thread length |
Spanner No. (octagon) |
Pack.
pcs. |
Art. No. |
| C |
L |
E |
A |
B |
| [mm] |
|
MWE 75M/63
|
M75x1,5 / 63
|
60
|
40
|
22
|
88
|
86
|
1
|
E03DK-08010300401
|
|
MWE 90M/75
|
M90x2 / 75
|
74
|
44
|
23
|
106
|
102
|
1
|
E03DK-08010300501
|
|
MWE 110M/100
|
M110x2 / 100
|
96
|
50
|
28
|
134
|
130
|
1
|
E03DK-08010300601
|
Note!
Glands without lock nut, with sealing washer.
Steel gland for protective
conduits, MWD...S type IP66
Material:
stainless steel+polyethylene.
Working
temperature: -5÷+80
°C (without moving -20 °C)
|
Type
|
Thread
PG
|
Min. internal diameter
C
[mm]
|
Height
L
[mm]
|
Thread
length
E
[mm]
|
Spanner
No.
[mm]
|
Pack [pcs.]
|
Art. No.
|
|
A
|
B
|
|
MWD 7S
|
P 7
|
7,5
|
10,0
|
6
|
19
|
17
|
50
|
E03DK-08020100101
|
|
MWD 9S
|
P 9
|
9,2
|
12,5
|
6
|
22
|
20
|
50
|
E03DK-08020100201
|
|
MWD 11S
|
P 11
|
11,9
|
13,0
|
7
|
27
|
24
|
50
|
E03DK-08020100301
|
|
MWD 13S
|
P 13,5
|
13,6
|
13,0
|
7
|
29
|
26
|
50
|
E03DK-08020100401
|
|
MWD 16S
|
P 16
|
15,3
|
14,0
|
7
|
30
|
28
|
50
|
E03DK-08020100501
|
|
MWD 21S
|
P 21
|
20,2
|
16,5
|
8
|
36
|
34
|
25
|
E03DK-08020100601
|
|
MWD 29S
|
P 29
|
26,7
|
19,5
|
8
|
47
|
45
|
25
|
E03DK-08020100701
|
|
MWD 36S
|
P 36
|
34,6
|
26,5
|
10
|
60
|
56
|
10
|
E03DK-08020100801
|
|
MWD 48S NFC
|
P 48 NFC
|
45,3
|
33,0
|
10
|
74
|
70
|
10
|
E03DK-08020100901
|
Note!
Nuts
and gland seals have to be ordered separately.
Grounding insert, WE type
Used in
the case where an electrical connect
between the gland and conduit is required. The WI insert must be
removed from the gland and replaced with the grounding insert. The
insert is delivered separately to be
replaced by the customer.
Material:
brass+poliethylene.
Working
temperature: -20÷+80
°C.
Used for the glands:
MWD and MWD...S.
|
Type
|
Art. No.
|
|
WE 7
|
120-436000
|
|
WE 9
|
120-436010
|
|
WE 11
|
120-436020
|
|
WE 13
|
120-436030
|
|
WE 16
|
120-436040
|
|
WE 21
|
120-436050
|
|
WE 29
|
120-436060
|
|
WE 36
|
120-436070
|
|
WE 48
|
120-436080
|
Note!
Inserts
WE for MWD ISO choose according to WO, WOT conduit.
Insulating insert, WI type
Spare
part for the MWD, MWD...S gland.
Material:
polietylene.
Working
temperature: -20÷+80
°C
|
Type
|
Art. No.
|
|
WI 7
|
120-436100
|
|
WI 9
|
120-436110
|
|
WI 11
|
120-436120
|
|
WI 13
|
120-436130
|
|
WI 16
|
120-436140
|
|
WI 21
|
120-436150
|
|
WI 29
|
120-436160
|
|
WI 36
|
120-436170
|
|
WI 48
|
120-436180
|
Note!
Inserts
WI for MWD ISO choose according to WO, WOT
conduit.
Insulating gland for protective
conduits, WD and WD...M types IP54
Used as
a termination of spiral protective
conduits WTG where cables are inserted into the inside of electrical
devices. The tube is screwed into the gland.
Material:
polyamid 6.6.
Colour:
black.
Working
temperature:
-30÷+90 °C.
|
Type
|
Thread/cond.
PG/WTG
|
Internal diameter
C
[mm]
|
Height
L
[mm]
|
Thread
length
E
[mm]
|
Spanner
No.
A
[mm]
|
Item No.
|
|
WD 9/7
|
P9/7
|
8,0
|
11,5
|
7
|
19
|
120-455020
|
|
WD 11/11
|
P11/11
|
11,0
|
12,0
|
8
|
22
|
120-455030
|
|
WD 13/13
|
P13,5/13
|
13,5
|
13,0
|
9
|
24
|
120-455040
|
|
WD 16/16
|
P16/16
|
15,5
|
13,5
|
9
|
27
|
120-455050
|
|
WD 21/21
|
P21/21
|
19,5
|
16,5
|
10
|
32
|
120-455060
|
|
WD 36/36
|
P36/36
|
36,0
|
18,5
|
14
|
55
|
120-455080
|
|
WD 48NFC/48
|
P48NFC/48
|
47,0
|
23,0
|
16
|
65
|
120-455100
|
|
Type
|
Thread/cond.
PG/WTG
|
Internal diameter
C
[mm]
|
Height
L
[mm]
|
Thread
length
E
[mm]
|
Spanner
No.
A
[mm]
|
Item No.
|
|
WD 16M/7
|
M 16x1,5 / 7
|
8,0
|
11,5
|
7
|
20
|
120-455230
|
|
WD 20M/11
|
M 20x1,5 / 11
|
11,0
|
12,0
|
8
|
24
|
120-455242
|
|
WD 20M/13
|
M 20x1,5 / 13
|
13,5
|
13,0
|
9
|
24
|
120-455243
|
|
WD 25M/16
|
M 25x1,5 / 16
|
15,5
|
13,5
|
9
|
27
|
120-455254
|
|
WD 32M/21
|
M 32x1,5 / 21
|
19,5
|
16,5
|
10
|
36
|
120-455265
|
|
WD 50M/36
|
M 50x1,5 / 36
|
36,0
|
18,5
|
14
|
54
|
120-455287
|
Note!
Nuts
black (BK) and gland seals have to be ordered separately.
Insulating gland for protective
conduits, WPD type IP66
Recommended
for WTG
type conduits. The gland body can
be turned in relation to the PG threaded element, so the condiut
can be screwed in by turning the gland body fixed to the box (cabinet).
Made
in accordance with:
DIN 40430.
Material:
PVC
UL 94 V0.
Colour:
black (RAL 9005).
Working
temperature:
-20°÷+70°C.
Minimum
mounting temperature: -5 °C.
|
Type
|
Thread/cond.
PG/WTG
|
Measures
[mm]
|
Item No.
|
|
A
|
B
|
C
|
e
|
E
|
L
|
|
WPD 7/7
|
P7/7
|
23
|
22
|
8
|
2,5
|
10
|
34
|
120-445290
|
|
WPD 9/9
|
P9/9
|
25
|
24
|
10,0
|
2,5
|
10,0
|
15
|
120-445300
|
|
WPD 11/9
|
P11/9
|
25
|
24
|
10,0
|
2,5
|
10,0
|
16
|
120-445310
|
|
WPD 13/13
|
P13,5/13,5
|
30
|
29
|
13,0
|
2,5
|
12,5
|
25
|
120-445320
|
|
WPD 16/16
|
P16/16
|
33
|
33
|
16,0
|
3,0
|
12,5
|
29
|
120-445330
|
|
WPD 21/21
|
P21/21
|
38
|
36
|
20,0
|
2,5
|
12,5
|
23
|
120-445340
|
|
WPD 29/29
|
P29/29
|
45
|
43
|
25,0
|
4,0
|
15,0
|
62
|
120-445350
|
|
WPD 36/36
|
P36/36
|
60
|
58
|
38,2
|
4,0
|
17,5
|
55
|
120-445360
|
|
WPD 48/48
|
P48/48
|
70
|
70
|
47,8
|
3,5
|
19,5
|
55
|
120-445370
|
Note!
Nuts
black (BK) and gland seals have to be ordered separately.
Elbow insulating gland for
protective conduits, WKD type IP66
Recommended
for WTG
type conduits. The tube is
screwed into the gland. Before that the rubber insert of glands is
screwed on the end of conduit.
Material:
polypropylene.
Colour:
black.
Working
temperature:
-30÷+90 °C.
|
Type
|
Thread/cond.
PG/WTG
|
Measures
[mm]
|
Item No.
|
|
A
|
B
|
C
|
H
|
E
|
L
|
|
WKD 11/9
|
P 11/9
|
25
|
24
|
29
|
35
|
12
|
60
|
120-445030
|
|
WKD 13/13
|
P 13,5/13
|
31
|
28
|
29
|
42
|
13
|
65
|
120-445040
|
|
WKD 21/21
|
P 21/21
|
38
|
35
|
44
|
55
|
15
|
80
|
120-445060
|
|
WKD 29/29
|
P 29/29
|
48
|
44
|
50
|
70
|
15
|
95
|
120-445070
|
Note!
Glands
with nuts in a kit (without seal).
2008-07-03
|