Solar collector Black Chromium
Technical parameters
| Type |
A2 Cr |
A2 Cr/M |
B2 Cr |
B2 Cr/M |
| Version |
- |
Vertical |
Vertical |
Horizontal |
Horizontal |
| Collector’s surface |
[m²] |
1,92 |
1,92 |
1,92 |
1,92 |
| Absorber’s surface |
[m²] |
1,70 |
1,70 |
1,70 |
1,70 |
| Length [A] |
[mm] |
1953 |
1953 |
1953 |
1953 |
| Width [B] |
[mm] |
981 |
981 |
981 |
981 |
| Height [H] |
[mm] |
104 |
104 |
104 |
104 |
| Volume of the fluid inside collector |
[dm³] |
~0,9 |
~0,9 |
~1,0 |
~1,0 |
| Casing |
- |
Aluminum tank |
Aluminum tank |
Aluminum tank |
Aluminum tank |
| Casing’s colour |
- |
No painted |
Colour brown
(RAL 8019) |
No painted |
Colour brown
(RAL 8019) |
| Absorber’s cover |
- |
Black chromium |
Black chromium |
Black chromium |
Black chromium |
| Absorption coefficient |
|
α > 0,96±0,01 |
α > 0,96±0,01 |
α > 0,96±0,01 |
α > 0,96±0,01 |
| Emission coefficient |
- |
ε < 0,10±0,02 |
ε < 0,10±0,02 |
ε < 0,10±0,02 |
ε < 0,10±0,02 |
| Max working temperature |
[ºC] |
100 |
100 |
100 |
100 |
| Permissible temp. without circulation |
[ºC] |
180 |
180 |
180 |
180 |
| Max working pressure |
[bar] |
6 |
6 |
6 |
6 |
| Weight |
[kg] |
39 |
39 |
39 |
39 |
| Insulation |
[mm] |
50 wool |
50 wool |
50 wool |
50 wool |
| Collector cover |
- |
Hardened solar
glass – thickness
4 mm |
Hardened solar
glass – thickness
4 mm |
Hardened solar
glass – thickness
4 mm |
Hardened solar
glass – thickness
4 mm |
Solar Collector
Technical parameters
| Type |
A2 S |
A2 S/M |
B2 S |
B2 S/M |
| Version |
- |
Vertical |
Vertical |
Horizontal |
Horizontal |
| Collector’s surface |
[m²] |
1,92 |
1,92 |
1,92 |
1,92 |
| Absorber’s surface |
[m²] |
1,70 |
1,70 |
1,70 |
1,70 |
| Length [A] |
[mm] |
1953 |
1953 |
1953 |
1953 |
| Width [B] |
[mm] |
981 |
981 |
981 |
981 |
| Height [H] |
[mm] |
104 |
104 |
104 |
104 |
| Volume of the fluid inside collector |
[dm³] |
~0,9 |
~0,9 |
~1,0 |
~1,0 |
| Casing |
- |
Aluminum tank |
Aluminum tank |
Aluminum tank |
Aluminum tank |
| Casing’s colour |
- |
No painted |
Colour brown
(RAL 8019) |
No painted |
Colour brown
(RAL 8019) |
| Absorber’s cover |
- |
Special cover |
Special cover |
Special cover |
Special cover |
| Absorption coefficient |
|
α > 0,95±0,20 |
α > 0,95±0,20 |
α > 0,95±0,20 |
α > 0,95±0,20 |
| Emission coefficient |
- |
ε < 0,05±0,02 |
ε < 0,05±0,02 |
ε < 0,05±0,02 |
ε < 0,05±0,02 |
| Max working temperature |
[ºC] |
100 |
100 |
100 |
100 |
| Permissible temp. without circulation |
[ºC] |
180 |
180 |
180 |
180 |
| Max working pressure |
[bar] |
6 |
6 |
6 |
6 |
| Weight |
[kg] |
39 |
39 |
39 |
39 |
| Insulation |
[mm] |
50 wool |
50 wool |
50 wool |
50 wool |
| Collector cover |
- |
Hardened solar
glass – thickness
4 mm |
Hardened solar
glass – thickness
4 mm |
Hardened solar
glass – thickness
4 mm |
Hardened solar
glass – thickness
4 mm |
Solar collectors installations
Storage tanks
Solar groups
|
Description |
Name
(Item no.) |
 |
Complete solar group consisting of:
• solar pump 20/6,
• check valve,
• ball valve,
• thermometer,
• manometer,
• safety
valve 6 bars,
• valve for filling up the
installation,
• terminal ¾ GW. |
Solar Group
FlowCon – RS
(773-000019) |
 |
Double solar group consisting of:
• solar pump 20/6,
• two gravitational valves,
• ball valve,
• thermometer,
• manometer,
• safety
valve 6 bars,
• valve for filling up the
installation,
• flow meter
1÷13 l/min ,
• permanentny odpowietrznik (Air - Stop),
• connection set of equalizing vessel together with assembly jig. |
Solar Group
FlowCon – FA
(773-000027) |
Microprocessor controllers
|
Description |
Name
(Item no.)
|
 |
Electronic
controller applied in solar installations guarantee proper and
effective system operation. The controller has 3 temperature sensors
as a standard:
– temperature sensor of solar circulation installed inside the solar collector
– temperature sensor of the water installed inside the accumulative reservoir
– additional temperature sensor dependent on configuration
Solar system controller switches on the pump of collector circulation
only then when the temperature inside the collector is higher than the
temperature in the storage reservoir by given value. When the
difference of temperatures between collector and reservoir will
decrease to switching off value at the controller the pump is shut
down. In order to secure the installation against over-heating, the
controller is set at max. temperature (Tmax) to which water in the
storage reservoir can be heated. After reaching this temperature the
controller will shut down the circulation pump independently on the
difference of temperatures between collector and reservoir. After
switching of the pump temperature inside the collector may rise above
100 ºC, what is not so dangerous if the cumulative reservoir
gathers evaporated heating fluid from the collector.. After decreasing
temperature in accumulative reservoir below Tmax and cooling down the
collector, solar installation restarts its work. Controller G 403 P04
is an independent regulation block in special casing made from two
parts. Working parameters can be justified to actual working conditions
and type of installation. Such controller can work in the following
systems:
1. Controlling solar system pump for heating the water
2. Controlling solar system pump and servicing the pump which charges the storage reservoir from central heating boiler
3. Controlling solar system pump and stirring pump between reservoir
connected to solar collectors and reservoir cooperating with central
heating boiler
4. Controlling solar system pump and three-pass valve for the system with the exchanger of swimming pool
5. Controlling solar system pumps in version with solar collectors placed on two separate roofs
6. Controlling solar system pump and three-pass valve for the system supported with central heating |
Controller
GECO
G - 403
(773-000008) |
Housing for
Controller
GECO
(773-000009) |
Solar installation accessories
|
Description |
Name
(Item no.) |
 |
Straight, self-locking connector Ø18 mm
|
Self-locking connector
(773-000002) |
 |
Muff connector GW Ø18 x ½”
|
Muff connector
(773-000012) |
 |
Elbow self-locking connector Ø18 mm
|
Elbow connector
(773-000004) |
 |
Self-locking pipe tee Ø18 mm
|
Self-locking pipe tee
(773-000003) |
 |
Double-locking pipe tee 18 x GW½” x 18
|
Double-locking pipe tee
(773-000011) |
 |
Plug ½
|
Plug
(773-000015) |
 |
Immersion sleeve ½ used as a shield of temperature sensor.
Assembled at the place of installation.
|
Immersion sleeve
(773-000010) |
 |
Automatic vent valve ½ with cut-off valve. Max. working
pressure 6 bars.
|
Vent ½
(773-000018) |
 |
Hand operated pump for filling up solar installations with valve GZ
½ , 15 mm terminal pipe. Ability for gaining the pressure of 4 bars.
|
Hand operated pump
(773-000013) |
 |
Diaphragmatic cylinder designed for working in solar installations.
Max. working temp. 120 ºC. Terminal – ¾” GZ.
|
Diaphragmatic cylinder 18 l
(773-000005) |
Diaphragmatic cylinder 25 l
(773-000016) |
Trim for diaphragmatic
cylinder
(773-000024) |
 |
Terminal for diaphragmatic cylinder: Length – 50 cm, Terminal
– ¾”
|
Terminal for diaphragmatic
cylinder
(773-000042) |
 |
Cleading K-FLEX EC designed for solar installations is made of
synthetic rubber. Insulation is made of very elastic material which is characterized by closed cell
structure, high coefficient of resistance to diffusion of steam water and low heat conductivity.
Resistance to UV radiation and other external conditions is up to 120 ºC.
|
Lag 9x18
(773-000028) |
Lag 13x18
(773-000029) |
Lag 19x18
(773-000030) |
Lag 9x22
(773-000031) |
Lag 13x22
(773-000032) |
Lag 19x22
(773-000033) |
Lag HT-175 13x28
(773-000026) |
 |
Liquid in solar installations is water solution of propylene glycol
which consists of inhibitors ensuring perfect anti-corrosion properties. Crystallization temp.
– 25 ºC.
|
ERGOLID EKO fluid 20 l
(773-000006) |
Fastening sets
|
Description |
Name
(Item no.) |
 |
Roof holder screw down directly on to roof rafters, it used for
mounting crosswise slat.
|
Element A
(770-R01001) |
 |
Element A1
(770-R01002) |
 |
Mounting slat for solar collectors:
1. vertical collectors:
• Element B1/vertical 1140 mm,
• Element B2/vertical 2190 mm,
• Element B3/vertical 3230 mm,
• Element B4/vertical 4300 mm,
• Element B5/vertical 5360 mm
2. horizontal collectors
• Mounting slat B1/horizontal 2140 mm,
• Mounting slat B2/ horizontal 4190 mm,
• Mounting slat B3/ horizontal 6240 mm.
|
Mounting slat B1/horiz.
(770-P01004) |
Mounting slat B1/vert
(770-P02001) |
Mounting slat B2/horiz.
(770-P01005) |
Mounting slat B2/vert
(770-P02002) |
Mounting slat B3/horiz.
(770-P01006) |
Mounting slat B3/vert
(770-P02003) |
Mounting slat B4/horiz.
(770-P01007) |
Mounting slat B5/horiz.
(770-P01008) |
 |
Grip for mounting slat preventing collector from sliding form
assembly bus bar.
|
Grip E
(770-P01012) |
 |
Clamp for fixing solar collectors on mounting slat in tank shape.
Type: Grip DP – right, Grip DL – left
|
Grip DP
(770-R01031) |
Grip DL
(770-R01030) |
 |
Grip for fixing solar collector on mounting slat, applied between
two panels.
|
Grip CD
(770-R01032) |
 |
Supporting bracket for fixing the mounting slat.
|
Bracket L/horiz.
(770-P01029) |
Bracket L1
(770-P01015) |
 |
Supporting bracket for fixing mounting slat, installed on roof patch
|
Bracket P
(770-P01033) |
Bracket P1
(770-R01017) |
 |
Supporting bracket for fixing the bracket, applied in covering the
roof
with corrugated elements.
|
Bracket R
(770-R01019) |
 |
Supporting bracketl for fixing the bracket, applied in angle
installation of solar collectors.
|
Bracket X
(770-R01029) |
 |
Supporting bracket for fixing mounting slat.
|
Mounting beam F/horiz.
(770-R01003) |
Mounting beam F/vert
(770-R02001) |
 |
Supporting bracket for fixing suspending elements, applied while angle
mounting on the roof.
|
Mounting beam G/horiz.
(770-R01004) |
Mounting beam G/vert
(770-R02001) |
 |
Supporting bracket for fixing mounting slat, applied while angle
mounting on the roof.
|
Mounting beam H/horiz.
(770-R01006) |
Element H/vert
(770-R02001) |
 |
Supporting bracket - support for fixing suspending elements, applied
while angle mounting on the roof.
Type: Element K – for vertical collectors,
Element K/vert – for horizontal collectors.
|
Mounting beam K10/horiz.
(770-R01007)
|
Mounting beam K15/horiz.
(770-R01008) |
Mounting beam K20/horiz.
Mounting beam K20/horiz.
Элемент
K20/horiz.
(770-R01008) |
Mounting beam K25/horiz.
(770-R01010) |
Mounting beam K30/horiz.
(770-R01011) |
Mounting beam K35/horiz.
(770-R01012) |
Mounting beam K40/horiz.
Mounting beam K40/horiz.
Элемент
K40/horiz.
(770-R01013) |
Mounting beam K45/horiz.
(770-R01014) |
Mounting beam K10/vert
(770-R02005) |
Mounting beam K15/vert
(770-R02006) |
Mounting beam K20/vert
(770-R02007) |
Mounting beam K25/vert
(770-R02008) |
Mounting beam K30/vert
(770-R02009) |
Mounting beam K35/vert
(770-R02010) |
Mounting beam K40/vert
(770-R02011) |
Mounting beam K45/vert
(770-R02012) |
 |
Roof holder screw down directl y on to roof rafters, it used for
mounting crosswise slat.
|
Bracket M
(770-P01031) |
 |
Bracket M1
(770-R01016) |
 |
Carrying
bracket – applied during installation of collectors with deviation towards
south direction |
Bracket W
(770-R01027) |
Bracket W1
(770-R01028) |
 |
Carrying
bracket – applied during installation of collectors with deviation towards
south direction (directly on grips) |
Bracket Z
(770-R01023) |
Bracket Z1
(770-R01024) |
 |
Mounting
beam adjusted for installation of collectors on the south wall of the building |
Mounting
beam FS/horiz.